The Rapid Temperature Change Test Chamber simulates rapid thermal cycling environments to accelerate thermal stress testing of electronics, automotive, and aerospace components, widely used for Environmental Stress Screening (ESS) and reliability validation.
*All products support non-standard customization.
| Model | DBH-252 | DBH-504 | DBH-720 | DBH-1000 | DBH-2000 |
|---|---|---|---|---|---|
| W*D*H(mm) Internal Size | W600*D600*H700 | W800*D700*H900 | W900*D800*H1000 | W1000*D1000*H1000 | W2000*D1000*H1000 |
| W*D*H(mm) External Size | W880*D1650*H1700 | W1080*D1750*H1900 | W1180*D1850*H2000 | W1280*D2050*H2000 | W2280*D2050*H2000 |
| Temperature Range | Low Temp :-40℃/-55℃/-70℃ High Temp:+150℃ |
||||
| Humidity Range | 10%~98% R.H | ||||
| Heating Rate | 3℃/min、5℃/min、10℃/min、15℃/min、20℃/min | ||||
| Cooling Rate | 3℃/min、5℃/min、10℃/min、15℃/min、20℃/min | ||||
| Temperature Type | Linear/Average | ||||
| Temperature Resolution | 0.01℃ | ||||
| Humidity Resolution | 0.1%R.H | ||||
| Temperature Uniformity | ≤2℃ | ||||
| Temperature Fluctuation | ≤±0.5℃ | ||||
| Temperature Deviation | ≤±2.0 ℃ | ||||
| Humidity Deviation | ±3.0%RH(>75%RH);±5.0%RH(≤75%RH) | ||||
| Humidity Fluctuation | ≤±2.0%RH | ||||
| Power Supply | 380V±10%,50Hz,3/N/PE | ||||
| Cooling Method | Water-cooled | ||||
| Humidity Sensor | Electronic Type | ||||
| Weight | appro.300KG | appro.600KG | appro.1000KG | appro.1200KG | appro.2500KG |