The High Altitude Test Chamber is a testing device designed to simulate low-pressure environments. It can accurately control parameters like internal pressure and temperature. Widely used in industries including electronics, automotive parts, and aerospace, it tests the performance stability of products under low-pressure conditions.
*All products support non-standard customization.
| Model | DBL-504 | DBL-1200 | DBL-1800 | DBL-17500 | DBL-52500 |
|---|---|---|---|---|---|
| Internal Dimension mm | W800×D700×H900 | W1500×D800×H1000 | W1800×D1000×H1000 | W2500×D2000×H3500 | W3500×D6000×H2500 |
| External Dimension mm | W1930×D2400×H2300 | W1960×D2350×H2080 | W2400×D3250×H2080 | W3000×D4000×H4370 | W6000×D7000×H3000 |
| Temperature Range | Low Temperature :RT/0℃/-40℃ High Temperature:+100℃ |
||||
| Pressure range | A: ATM(100kPa)~0.5kPa;B: ATM~1kPa;C: ATM~10kPa;D: ATM~20kPa;E: ATM~50kPa | ||||
| Heating Rate | ≥3℃/min | ||||
| Cooling Rate | ≥1℃/min | ||||
| Temperature Resolution | 0.01℃ | ||||
| Humidity Resolution | 0.1%RH | ||||
| Temperature Uniformity | ≤2℃ | ||||
| Temperature Fluctuation | ≤±0.5℃ | ||||
| Temperature Deviation | ≤±2.0℃ | ||||
| Pressure Reduction Rate | Atmospheric Pressure (ATM) → Low Pressure (100 kPa → Low Pressure): ≤ 30 minutes or ≤ 60 minutes | ||||
| Pressure Control Accuracy | ±2kPa | ||||
| Power Supply | 380V±10%, 50Hz, 3/N/PE | ||||
| Cooling Method | Air-cooled/Water-cooled | ||||
| Optional Items | Power cable/Liquid cooling/Communication cable/Temperature cable interfece | ||||
| Weight | appro.1300KG | appro.2800KG | appro.4000KG | appro.12000KG | appro.30000KG |
Copyright © Danbo Instrument (Kunshan) Co.,Ltd all reserved.